Whistler PRO-800W Marine Battery User Manual


 
17
ADDITIONAL FEATURES
In the event of automatic shut down or continuous
audible alarm, turn the inverter rocker switch to the OFF
(O) position until the source of the related problem has
been identified and resolved.
Wall Mounting:
The Pro-800W has provisions for wall mounting;
slotted holes allow for easy wall mounting of the unit.
For You Television Fans and Audiophiles.
Although the inverter is shielded and filtered to minimize
signal interference, some interference with your television
picture may be unavoidable, especially with weak signals.
However, here are some suggestions that may improve
the reception.
1. First, make certain that the television antenna pro
duces a clear signal under normal operation
conditions (i.e., at home plugged into a standard
110AC wall outlet). Also, ensure that the antenna
cable is properly shielded and of good quality
2. Change the relative positions of the inverter, antenna
cables and television power cord.
3. Isolate the television, its power cord and antenna
cables and television power cord.
4. Coil the television power cord and the input cables
running from the 12 volt power source to the inverter.
ADDITIONAL FEATURES
16
Automatic Shut Down & Related Safety Features.
Each Whistler inverter model has an unique LED Indicator
warning light system which operates in conjunction with
the automatic shut down feature. These indicator lights
operate as follows:
GREEN LED: System ready.
RED LED: System overload/automatic shut down.
Your inverter will shut down automatically when any of the
following problems occur:
1. The power input from the battery drops below
10 volts.
2. The power input from the battery exceeds 15.5+/-0.5
volts.
3. The continuous draw of the appliance or equipment
being operated exceeds the design parameters of the
inverter.
The inverter is equipped with the following additional safety
features:
1. Thermal Cut Off
Automatic shut down if internal temperature exceeds safe
design parameters.
2. Low Battery Voltage Alarm/Shutdown Protection
a) When the input voltage from the 12 volt power
source drops below 10.5 volts, an audible tone will
be heard. This is the low battery voltage alarm.
b) The inverter will automatically shut down when the
input voltage drops below 10 volts. This protects the
battery from completely draining.
pro800w.qxp 4/30/2010 9:00 AM Page 19