Xantrex Technology 806-1840-02 Marine Battery User Manual


 
975-0390-01-01 45
Specifications
NOTE: These specifications refer to charger mode.
AC Input 1000-watt models 1500 and 1800-watt models
Operating voltage range for all models 90–130 VAC 90–130 VAC
Operating voltage range for Freedom HF 1500
and Freedom HF 1800 T
5 AAC at 20 A charge, 120 VAC IN 10 AAC at 40 A charge, 120 VAC IN
Nominal current 5 AAC at 20 A charge, 120 VAC IN 10 AAC at 40 A charge, 120 VAC IN
Nominal frequency 60 Hz 60 Hz
DC Output 1000-watt models 1500 and 1800-watt models
Nominal voltage 12.0 VDC 12.0 VDC
Min battery voltage for charging 0.0 VDC 0.0 VDC
Max output voltage 14.4 VDC 14.4 VDC
Nominal output current User selectable:
2A, 5A, 10A, 20A (Freedom HF 1000)
5A, 15A, 35A, 55A (Freedom HF 1055)
User selectable:
2A, 10A, 20A, 40A
Charger current derating Charger current will automatically derate as
internal temperature exceeds 80 °C.
Charger current will automatically derate as
internal temperature exceeds 80 °C.
Efficiency at nominal output 75% 75%
Other 1000-watt models 1500 and 1800-watt models
No load input power (producing output voltage) 10W 10W
Off mode current draw 1mA 1mA
Regulatory Approvals 1000-watt models 1500 and 1800-watt models
ETL approved to CSA 107.1, UL458, and UL458 Marine Supplement (drip shield with product
number 808-9531 required).
Freedom HF InvChg Owners Guide.book Page 45 Tuesday, April 29, 2014 12:10 PM