4-19
E
●
Shift cable (reverse gate end)
●
Intermediate housing
Using a grease gun, fill the intermediate
housing with water-resistant grease
through the grease nipple 1.
Grease quantity:
Initial 10 hours or 1 month:
33.0–35.0 cm
3
(1.11–1.18 oz)
Every 100 hours or 12 months:
6.0–8.0 cm
3
(0.20–0.27 oz)
UF1B12.book Page 19 Monday, July 7, 2003 1:48 PM