ENGLISH
Copyright 2009 ZyXEL Communications Corporation
C
If you cannot connect to the Internet, make sure the
OLT has Internet access and the ONU5100-B22 is
registered with the OLT successfully.
If the ONU5100-B22 cannot register with the OLT,
• Check the connector on the optical cable and the PON
port. Make sure they are clean and dust-free. Use an
air duster to clean the connectors. Do NOT use a wet
cloth to clean the connectors.
• Check the optical cable. Make sure it is not broken. If
the cable is broken, contact your service provider to
have the cable/connector replaced.
Specifications
Specifications are accurate at the time of writing.
Feature Specification
Dimensions (mm) 75 (Wide) x 14 (Deep) x 12.4 (High)
Weight < 1 kg
Power Supply + 3.3V
Power Consumption < 2 W
Case Operation
Temperature
0 ºC ~ 70 ºC
Storage
Temperature
-40 ºC ~ 85 ºC
Safety Warnings
• Ground yourself (by properly using an anti-static wrist strap for
example) whenever working with the device's hardware or
connections.
• Do NOT use this product near water, for example, in a wet basement
or near a swimming pool.
• Do NOT expose your device to dampness, dust or corrosive liquids.
• Do NOT store things on the device.
• Do NOT install, use, or service this device during a thunderstorm.
There is a remote risk of electric shock from lightning.
• Connect ONLY suitable accessories to the device.
• Do NOT open the device or unit. Opening or removing covers can
expose you to dangerous high voltage points or other risks. ONLY
qualified service personnel should service or disassemble this
device. Please contact your vendor for further information.
• Make sure to connect the cables to the correct ports.
• Place connecting cables carefully so that no one will step on them or
stumble over them.
• Always disconnect all cables from this device before servicing or
disassembling.
Operation Humidity 0% ~ 85% (non-condensing)
Storage Humidity 0% ~ 95% (non-condensing)
PON Interface One PON port (single fiber link)
Compliant with IEEE 802.3ah
PX-20
SC optical connectors with shutters
Transmission distance: 20 km
Wavelength: 1310 nm upstream and
1490 nm downstream
Full duplex
Feature Specification
• Use ONLY an appropriate power adaptor or cord for your device.
• Do not use the device outside, and make sure all the connections
are indoors. There is a remote risk of electric shock from lightning.
• Make sure that the cable system is grounded so as to provide some
protection against voltage surges.
Your product is marked with this symbol, which is known
as the WEEE mark. WEEE stands for Waste Electronics
and Electrical Equipment. It means that used electrical
and electronic products should not be mixed with
general waste. Used electrical and electronic equipment
should be treated separately.