![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/6/8e/68e05e19-d657-444b-a72a-dd7fe49d4c1b/68e05e19-d657-444b-a72a-dd7fe49d4c1b-bg2c.png)
40
1. FAN (BLOWER) Output L.E.D. (light emitting diode) Indicator
a. If the dryer is started and the blower motor is not operating, yet the Phase 6 OPL microprocessor
controller (computer) display fan indicator dot and power supply input L.E.D. (light emitting diode)
are on, but the fan output L.E.D. is off, then the fault is the Phase 6 OPL microprocessor controller
(computer) itself.
1) If the motor
is not operating. The fan indicator dot and output L.E.D. (light emitting diode) are
also on, then the problem (fault) is elsewhere (i.e., external of the Phase 6 OPL microprocessor
controller [computer]).
2. FOR (FORWARD) Output L.E.D. (light emitting diode) Indicator (for optional reversing
model ONLY)
a. If the dryer is started and the blower motor is operating, but the drive (tumbler/basket) motor is not,
yet the Phase 6 OPL microprocessor controller (computer) display FORWARD indicator dot is on,
the FOR (FORWARD) motor output L.E.D. (light emitting diode) is off; then the fault is the Phase
6 OPL microprocessor controller (computer) itself.
1) If the drive tumbler (basket) motor
is not operating and the forward indicator dot and output
L.E.D. (light emitting diode) is on; then the problem (fault) is elsewhere (i.e., external of the
Phase 6 OPL microprocessor controller [computer]).
3. REV (REVERSE) Output L.E.D. (light emitting diode) Indicator (for optional reversing
models ONLY)
a. If the dryer is started and the blower motor is operating but the drive (tumbler and basket) motor is
not, yet the Phase 6 OPL microprocessor controller (computer) displays REVERSE indicator dot is
on but the REV (REVERSE) motor output L.E.D. (light emitting diode) is off; then the fault is of
the Phase 6 OPL microprocessor controller (computer) itself.
1) If the drive tumbler (basket) motor
is not operating and reverse indicator dot and output L.E.D.
(light emitting diode) is on; then the problem (fault) is elsewhere (i.e., external of the Phase 6 OPL
microprocessor controller [computer]).
4. AIR (AIR JET) Output L.E.D. (light emitting diode) Indicator - OPTIONAL
a. AIR is on with the display dot at the end of the dry cycle once the display reads dONE, it is on for
approximately 60-seconds and the output L.E.D. (light emitting diode) indicator and the display dot go
out. If the air jet DOES NOT energize it is not the fault of the Phase 6 OPL microprocessor
controller (computer). If the output L.E.D. (light emitting diode) or dot DO NOT go on it is the fault
of the Phase 6 OPL microprocessor controller (computer).
5. HT1 (HEAT) Output L.E.D. (light emitting diode) Indicator
a. If the dryer is started and there is No Heat yet the Phase 6 OPL microprocessor controller (computer)
display heat circuit indicator dot is on, but the HT1 output L.E.D. (light emitting diode) indicator is
off; then the fault is in the Phase 6 OPL microprocessor controller (computer) itself.
1) If the dryer is started and there is No Heat yet both the Phase 6 OPL microprocessor controller
(computer) display indicator dots and the HT1 output L.E.D. (light emitting diode) indicator are
on; then the problem (fault) is elsewhere (i.e., external of the Phase 6 OPL microprocessor
controller [computer]).