Appendix B: Image File Download Using OIDs
B-4 SEHI100TX User’s Guide
• Enter the IP address of the TFTP server in standard dotted decimal
notation (e.g., 132.177.118.24).
• Enter the FULL path to the image file in the ctDLTFTPRequest OID,
including the name of the image file (e.g., c:\tftpboot\sehi.hex).
Table B-1 OIDs and Settings
Step OID Name OID Number
Data
Type
SNMP OID
Data
1. ctDLForceOnBoot 1.3.6.1.4.1.52.4.1.5.8.1.1.0 integer 1
2. ctDLCommitRAMToFlash 1.3.6.1.4.1.52.4.1.5.8.1.2.0 integer 1
3. ctDLTFTPRequestHost 1.3.6.1.4.1.52.4.1.5.8.1.4.0 IP
address
Enter the IP
address of
the TFTP
server.
4. ctDLTFTPRequest 1.3.6.1.4.1.52.4.1.5.8.1.5.0 string
(ASCII)
Enter the
path to the
image file.
5. ctDLInitiateColdBoot 1.3.6.1.4.1.52.4.1.5.8.1.3.0 integer 1