68
SmartStack STS16-20D/STS16-20R Token Ring Switches Installation and User Guide Installation
Table 12. Inter-box Parameters
Checking the Installation
The SmartStack STS16-20D/STS16-20R performs a diagnostic self-test during the
power on cycle. From a management console, check that the switch lists the
SmartStack STS-LM port along with the switch ports and that there are no error
messages. The SmartStack STS-LM port will be listed as port 29.
If, after installation, there is poor system performance or the SmartStack STS-LM
module does not work at all, remove the module and check for any damaged or bent
connector pins. You may need a bright light to see inside the stacker slot to check
for bent pins. Also, verify that the module is set firmly in place.
❏
Menu Parameter
IP Configuration IP Address, IP Gateway, IP Subnet, IP State
Spanning Tree
Protocol
STP Enabling/Disabling, STP Switch Priority, STP
Maximum Aging, STP Hello Time, STP Forward Delay
Virtual LAN
Name
Configuration
Changing VLAN names
Password System password
Console
Configuration
Console Time-out
Telnet
Configuration
Number of Allowed Telnet Sessions, Disallow New Telnet
Sessions
TFTP Download TFTP Server Address, Download Domain, Download
Filename
Switch/Stack
Information
Stack Timeout, System Name, System Contact, System
Location
SNMP
Configuration
Send Authentication Traps, changing the Trap table in any
way, changing the Community Name table in any way