Absolute Maximum Ratings
Operating Temperature
μV microvolts s sigma: one standard deviation
μVrms microvolts root-mean-square V volts
Table 5. Units of Measure (continued)
Symbol Unit of Measure Symbol Unit of Measure
Table 6. Absolute Maximum Ratings
Parameter Description Min Typ Max Unit Notes
T
STG
Storage Temperature –55 – +100 °C Higher storage temperatures
reduces data retention time.
T
A
Ambient Temperature with Power Applied 0 – +70 °C
Vdd Supply Voltage on Vdd Relative to Vss –0.5 – +6.0 V
V
IO
DC Input Voltage Vss – 0.5 – Vdd + 0.5 V
V
IO2
DC Voltage Applied to Tri-state Vss – 0.5 – Vdd + 0.5 V
I
MIO
Maximum Current into any Port Pin –25 – +50 mA
I
MAIO
Maximum Current into any Port Pin
Configured as Analog Driver
–50 – +50 mA
ESD Electro Static Discharge Voltage 2000 – – V Human Body Model ESD.
LU Latch Up Current – – 200 mA
Table 7. Operating Temperature
Parameter Description Min Typ Max Unit Notes
T
A
Ambient Temperature 0 – +70 °C
T
J
Junction Temperature 0 – +88 °C The temperature rise from
ambient to junction is
package specific. See
“Thermal Impedance” on
page 28. The user must limit
the power consumption to
comply with this
requirement.
[+] Feedback [+] Feedback