![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/1/92/1923071b-cc19-4714-b48b-135c1690183f/1923071b-cc19-4714-b48b-135c1690183f-bg8b.png)
Error Code Message Information
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Re-configure the system to minimum configuration, inspect and
reinstall system cables.
3. If the issue persists, see Getting Help.
VLT0225
Message The memory module <
name
> voltage is less than the lower critical
threshold.
LCD Message Memory module <
number
> <
name
> voltage is outside of range.
Details System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Re-configure the system to minimum configuration, inspect and
reinstall system cables.
3. If the issue persists, see Getting Help.
VLT0226
Message The memory module <
name
> voltage is greater than the upper
warning threshold.
LCD Message Memory module <
number
> <
name
> voltage is outside of range.
Details System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Re-configure the system to minimum configuration, inspect and
reinstall system cables.
3. If the issue persists, see Getting Help.
VLT0227
Message The memory module <
name
> voltage is greater than the upper critical
threshold.
LCD Message Memory module <
number
> <
name
> voltage is outside of range.
Details System hardware detected an over voltage or under voltage
condition.
139