EX470-en-GB_v5.6 4/15
13
Specifications
Function Range Resolution Accuracy
DC Voltage
400mV 0.1mV
(0.3% reading + 2 digits)
4V 0.001V
(0.5% reading + 2 digits)
40V 0.01V
400V 0.1V
1000V 1V
(0.8% reading + 3 digits)
AC Voltage
50 to 400Hz 400Hz to 1kHz
400mV 0.1mV
(1.5% reading + 15
digits)
(2.5% reading + 15digits)
4V 0.001V
(1.5% reading + 6
digits)
(2.5% reading + 8 digits)
40V 0.01V
400V 0.1V
750V 1V
(1.8% reading + 6
digits)
(3% reading + 8 digits)
DC Current
400A 0.1A
(1.5% reading + 3 digits)
4000A 1A
40mA 0.01mA
400mA 0.1mA
4A 0.001A
(2.5% reading + 5 digits)
20A 0.01A
AC Current
50 to 400Hz 400Hz to 1KHz
400A 0.1A
(1.8% reading + 8
digits)
(3.0% reading + 7 digits)
4000A 1A
40mA 0.01mA
400mA 0.1mA
4A 0.001A
(3.0% reading + 8
digits)
(3.5% reading + 10
digits)
20A 0.01A
Resistance
400 0.1 (0.8% reading + 4 digits)
4k 0.001k (0.8% reading + 2 digits)
40k 0.01k
(1.0% reading + 2 digits)
400k 0.1k
4M 0.001M
40M 0.01M (3.0% reading + 5 digits)
Capacitance 40nF 0.01nF
(5.0% reading + 7 digits)
400nF 0.1nF
(3.0% reading + 5 digits)
4F 0.001F
(3.5% reading + 5 digits)
40F 0.01F
100F 0.1F (5.0% reading + 5 digits)
Temp
(type-K)
-20 to 750C 1C (3.0% reading + 3 digits)
(probe accuracy not included)
-4 to 1382F 1F
Temp
(IR)
-50 to 270C 1C
2.0% reading or 2C, 4 F
-58 to 518F 1F
NOTE: Accuracy is stated at 18
o
C to 28
o
C (65
o
F to 83
o
F) and less than 75% RH.