![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/9/d6/9d62f1f2-c4df-474a-85ca-afe0fbbbc27b/9d62f1f2-c4df-474a-85ca-afe0fbbbc27b-bg27.png)
37
11. Technical Data
This cooker is designed for use on natural gas but can be used converted to LP (Propane X (2.54 kPa)).
A conversion kit from Natural Gas to Propane is supplied with the cooker.
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Cooker back, serial number repeater badge below oven door opening.
COUNTRY OF DESTINATION: Australia.
Connections
Gas (Rp ½ at rear right-hand side) Electric
Natural gas 1 kPa 230 V 50 Hz
Propane 2.54 kPa
See the appliance badge for test pressures.
Dimensions
Overall height minimum 900 mm maximum 925 mm
Overall width 1100 mm
Overall depth 600 mm to fascia; 650 mm over handles
Minimum space above the hotplate 650 mm
Refer to 'Positioning the Cooker'.
Ratings
Hotplate
Natural Gas 1 kPa LP Gas 2.54 kPa
Injector Bypass Injector Bypass
Wok burner 15.2 MJh
Internal 112
90 15.2 MJh
Internal 66
54
External 164 External 91
Large burner 12.3 MJh 165 80 12.0 MJh 89 41
Medium burner 6.2 MJh 115 56 6.2 MJh 67 33
Small burner 3.7 MJh 92 48 13.3 MJh 48 25
Oven Efficiency
Ovens
Left-hand oven Right-hand oven
Conventional Forced air convection
Maximum power output @ 230 V 50 Hz 2.2 kW 2.5 kW
Energy eciency class on a scale of A (more ecient) to G (less ecient) A A
Energy consumption based on standard load 0.99 kWh 0.90 kWh
Usable volume (litres) 67 69
Size Large Large
Time to cook standard load 40 minutes 38 minutes
Surface area of the grid 1400 cm
2
1400 cm
2
Grill 2.3 kW
Warmer 160 W
Maximum total electrical load at 230 V (approximate total including oven lights, oven fan, etc.): 7.3 kW.
DocAUS.101-0024 - Technical data - DF 110 - Classic-Toledo