A SERVICE OF

logo

46
SERIAL PORT SETUP
On the ADMINISTRATOR SETUP PAGE, click the SERIAL PORT button to display the SERIAL PORT SETUP window.
Specify whether to use the RS-232C or RS-485 interface, and set the communication parameters.
q TYPE (RS-232C)
Set up the RS-232C port usage. Select NONE,
MODEM/TA, WJ-SX550A, WJ-FS616, WJ-DR200 or
Serial Through.
The factory default setting is NONE.
w BAUD RATE (RS-232C)
Set the baud rate for RS-232C to 300, 1200, 2400,
4800, 9600, 14400, 19200, 38400, 57600, or 115200
bps can be selected.
The factory default setting is 4800 bps.
It is recommended that 38400 bps be selected for a 56
kbps modem, and 57600 bps when for a TA.
e DATA BIT (RS-232C)
Set the data bits for RS-232C.
The factory default setting is 8 bits.
r STOP BIT (RS-232C)
Set the stop bit for RS-232C.
The factory default setting is 1 bit.
t PARITY (RS-232C)
Set the parity bit for RS-232C.
The factory default setting is NONE.
y USE FLOW CONTROL (RS-232C)
Set flow control for RS-232C.
The factory default setting is NONE.
u TYPE (RS-485)
Set up the RS-485 port usage. Select NONE or CAM-
ERA + WJ-SX550A.
The factory default setting is NONE.
i BAUD RATE (RS-485)
Set the baud rate for RS-485 to 1200, 2400, 4800,
9600, 19200, or 38400 bps can be selected.
The factory default setting is 4800 bps.
o DATA BIT (RS-485)
Set the data bits for RS-485.
The factory default setting is 8 bits.
!0 STOP BIT (RS-485)
Set the stop bit for RS-485.
The factory default setting is 1 bit.
!1 PARITY(RS-485)
Set the parity bit for RS-485.
The factory default setting is NONE.
!2 X ON/X OFF (RS-485)
Set flow control for RS-485 (X ON/X OFF).
The factory default setting is OFF.
!3 DUPLEX MODE
Set the communication mode for RS-485.
The factory default setting is FULL DUPLEX.
q
w
e
r
t
y
u
i
o
!0
!1
!2
!3