![](https://pdfstore-manualsonline.prod.a.ki/pdfasset/7/cd/7cdf6871-8a68-435d-8866-277da3b1473f/7cdf6871-8a68-435d-8866-277da3b1473f-bg69.png)
D-1
7612-A2-GB20-10
November 1997
Standards Compliance for
SNMP Traps
D
Overview
This appendix describes the unit’s compliance with SNMP standards and any
special operational features for the SNMP traps supported. The unit supports
user interface traps and enterprise-specific traps.
Trap: warmStart
SNMP Trap Description Possible Cause
warmStart The unit has reinitialized itself.
The trap is sent after the unit
resets itself and stabilizes.
There are no variable-bindings.
H Reset command.
H Power disruption.
Trap: authentificationFailure
SNMP Trap Description Possible Cause
authenticationFailure Failed attempts to access the
unit.
There are no variable-bindings.
H SNMP message not properly
authenticated.
H Three unsuccessful attempts
were made to enter a correct
login/password combination.
H IP address security is
enabled, and a message was
received from SNMP
manager whose address was
not on the list of approved
managers.