47)
REGISTER C SET
LD/CD
Function: Changes the current setting of Register C. (Miscellaneous)
Format: Integer R C
Explanation: When power is turned ON, the Side Repeat function of Register C is
set to ON. If Function Switch 3 on the rear panel of the player is
ON (DOWN), the Load Start and Power-On Start functions of
Register C are also set to ON. If Function Switch 4 is ON (DOWN),
background color will be set to Black. Baud Rates of 9600 and
2400 cannot be set with this command. Note that some functions,
such as Test Mode, may suspend playback or disable further
control.
Test Mode is for use only by Authorized Service Centers, for
evaluating player operations.
The functions listed below can be set. To set a function to ON,
give the value indicated by the integer. To set multiple functions
to ON, the integer values must be added up. All eight functions can
be specified in combination by using the decimal values from 0 to
255. The completion status is returned immediately.
NOTE: When “Repeat Side”, “Chapter Repeat” or “Track Repeat” is
selected by the RCU, the “Side Repeat” function of Register C goes
to “ON” and when “Auto Return” is selected by the RCU, the “Side
Repeat” function of Register C goes to “OFF”.
Execution: * Initial value 0
3 R C <C/R> R <C/R>
* Side-Repeat, Load-Start to ON, background color BLUE
1 6 R C <C/R> R <C/R>
* Background Color BLACK; Side-Repeat and Load-Start to OFF
3-42 TP 120 v. 1.0 10/95 CLD-V2800 Level III User’s Manual
Chapter Three CLD-V2800 Level III
Integer Function 1 0
1 Side-Repeat ON OFF
2 Load-Start ON OFF
4 Power-on-Start ON OFF
8 (Not Used)
16 Background Color BLACK BLUE
32 TxD Terminator <CR+LF> <CR>
64 BAUD Rate 1200 4800
128 Test Mode ON OFF
Figure 3-U