3-154 G24-L AT Commands Reference Manual April 15, 2008
The following table shows the +MPCMC parameters.
Example
AT+MPCMC=?
+MPCMC:(0-1)
OK
AT+MPCMC=1
OK
AT+MPCMC?
+MPCMC: 1
OK
AT+MPCMC=0
OK
AT+MPCMC?
+MPCMC: 0
OK
Command
Type Syntax Response/Action Remarks
Set
+MPCMC=<flag> OK
or:
+CME ERROR: <err>
The Set command is used for setting
the PCM clock configuration.
Read
+MPCMC? +MPCMC: <flag>
OK
or:
+CME ERROR: <err>
The Read command returns the current
PCM clock <flag> value.
Test
+MPCMC=? +MPCMC: (list of
supported <flag>s)
OK
The Test command returns the possible
<flag> values.
Table 3-99: +MPCMC Parameters
<Parameter> Description
<flag> 0 Non-continuous PCM clock.
1 Continuous PCM clock.
Before the AT+MPCMC command is set for the first time,
this value is 0.
Power-up is according to the flex.