with the openings in the FCO. See Figure 6-10. The hinge surfaces should rest
flat against the rear of the library.
4. Using a Phillips screwdriver, secure the FCO to the rear of the library at the
FCO’s two top captive screws. See Figure 6-10.
5. Using two of the screws that were removed with the service panel, attach the
FCO’s two hinges to the rear of the library. See Figure 6-10.
Bottom Edge of
Service Panel Opening
Heatsink Panel
Screws (4)
Captive Screws (4)
FCO’s
Hinges (2)
Fibre Channel
Option
Executive PCBA
Screw Holes (6)
Figure 6-10 Rear View of TLS
6. Loosen the two top captive screws on the FCO that were tightened in step num-
ber four. Carefully guide the FCO backwards as it pivots on the hinges and
comes to its open position. See Figure 6-11.
6-12 FCO Type C Installation 501440 Rev. G