A SERVICE OF

logo

2-14 Sun StorEdge A3500 Hardware Configuration Guide September 1998
2.3 1x5 Cabling
2.3.1 SCSI Cabling
2.3.1.1 Cable Lengths
The following table shows the lengths of each SCSI cable connected to the drive
connections on the controller module.
The inboard IN/OUT connectors on each of the disk arrays are connected together
using a 0.2m SCSI jumper cable, part number 530-1883-xx.
The outboard IN/OUT-2 connector on each disk array is terminated with a
differential SCSI terminator, part number 150-1890-xx.
TABLE 2-6 Controller Module A (1x5)
SCSI Port Number Cable Length Part Number
1 2m 530-1885-xx
2 2m 530-1885-xx
3 2m 530-1885-xx
4 2m 530-1885-xx
5 2m 530-1885-xx