SER.
(15) AC inlet
Connect the supplied power cord to this socket.
(16) Monitor output terminal
• Monitor 1 output terminal
Outputs the Monitor 1's camera images.
• Monitor 2 output terminal
Outputs the Monitor 2's camera images.
(17) Audio input/output terminal
• Audio input terminal
This terminal is used for audio recording.
• Audio output terminal
Outputs audio input terminal signals during live
screen display, and outputs the recorded audio
during playback display.
(18) Video input terminal
Connect the camera to this terminal. Connecting
the camera automatically terminates the Digital
Video Recorder at 75 Ω.
(19) Video output terminal
A loop through output for the Video input
terminal. Connecting the BNC plug to the Video
output terminal automatically cancels the 75Ω
termination.
(20) 10BASE-T/100BASE-TX terminal
Use this terminal to remotely monitor or control
cameras connected to the Digital Video
Recorder or search or play back their recorded
images through the network using the web
browser from a PC.
(21) Alarm input terminal
Use this terminal to make Alarm event
recording. Connect no-voltage contact signals of
sensors, etc. to this terminal.
(22) Control input/output terminal
• Control output terminal
Outputs a signal during equipment failure
occurs.
• Priority recording input terminal
Use this terminal to begin Priority recording
using signals from connected external
equipment.
• Time sync input & output terminal
Use this terminal to synchronize the clocks of
multiple Digital Video Recorders used in the
system.
• Remote Control Input/Output Terminal B
Use this terminal for connection of the C-
RM1000 Remote Controller.
• Camera control terminal
Use this terminal to control the Combination
Camera.
Note
The C-RM1000 Remote Controller must be
connected to the Digital Video Recorder in
order to control the Combination Camera.
(23) Remote controller input/output terminal A
( Power can be supplied.)
Use this terminal to connect the C-RM1000
Remote Controller.