TEMPERATURE PROBE
Do not sharply bend and kink, or clamp
down on the capillary tube or damage may occur.
1. Drain shortening from fryer tank.
2. Disconnect smaller, 6-pin male connector.
(Temperature probe and drain valve interlock
(DVI) connector)
3. Remove the temperature probe lead wires from
pins 1 and 3 of the 6-pin male connector.
4. Remove GAS BURNERS as necessary.
5. Remove the probe retaining and packing nuts.
6. Remove screws securing probe mounting clips
and probe to the fryer heat tube (inside tank)
then remove probe.
7. Reverse procedure to install and check for
proper operation.
8. Check COOKING CONTROL CALIBRATION
under SERVICE PROCEDURES AND
ADJUSTMENTS.
HIGH LIMIT THERMOSTAT
Do not sharply bend and kink, or clamp
down on the capillary tube or damage may occur.
1. Drain shortening from fryer tank.
2. Remove GAS BURNERS as necessary.
3. Disconnect lead wires from high limit
thermostat.
F25377 (March 2010)Page 9 of 36