A SERVICE OF

logo

ER SERIES FRYER SERVICE MANUAL SUPPLEMENT - REMOVAL AND REPLACEMENT OF PARTS
F24696 (May 2001)Page 7 of 56
FILTER VALVE AND DISCARD
VALVE SWITCHES
WARNING:
DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. THERE ARE SEVERAL SEPARATE
CIRCUITS. BE SURE ALL ARE DISCONNECTED.
PLACE A TAG ON THE CIRCUIT BOX(ES)
INDICATING THE CIRCUIT IS BEING SERVICED.
1. Open the cabinet door to the fryer section being
serviced.
2. Disconnect lead wire connector from the
appropriate switch.
3. Remove switch mounting screws.
4. Reverse procedure to install.
NOTE:
Switch mounting is a fixed location and has
no provision for adjustment.
HEATER CONTACTORS
WARNING:
DISCONNECT THE ELECTRICAL
POWER TO THE MACHINE AT THE MAIN
CIRCUIT BOX. THERE ARE SEVERAL SEPARATE
CIRCUITS. BE SURE ALL ARE DISCONNECTED.
PLACE A TAG ON THE CIRCUIT BOX(ES)
INDICATING THE CIRCUIT IS BEING SERVICED.
1. Remove the front control panel as outlined under
"FRONT CONTROL PANEL" in "COVERS AND
PANELS".
2. Remove the combination mounting and cover
panel from the control area.
3. Contactors are now accessible.
NOTE
: Refer to "COMPONENT LOCATION".
4. Reverse procedure to install.