Specifications
Specifications Typical Value
Monitor type Impedance - Single Wire
Circuitry
Solid-state, surface mount
Alarm Audible and visual (LED)
Trip Level
6.5-7.0 megohms
Power
120VAC, 230VAC
Adjustments None Required
Calibration
None Required. Test Module available.
Item Code Size Weight Monitors
WSMONITOR1
.90" H x 1.8" W x 1.3" D 1.2 oz. One wrist strap/person
WSMONITOR2 1" H x 2.4" W x 2.3" D 1.6 oz. One wrist strap/person and work
surface
WSMONITOR3
1" H x 4" W x 2.4" D 2.6 oz. Two wrist straps/persons and work
surface
TMTOOL
Test Module for all WSMONITORS
Note: Adjustments or calibration is not required for the Continuous Monitors WSMONITOR1, WSMONITOR2, WSMONITOR3. The TMTOOL unit
simulates a correctly functioning person and wrist strap (Accept) and an open circuit (Reject). The TMTOOL also simulates high resistance for