Product Specications
Temperature Sensor: Precise spiral wound bi-metallic strip transducer
Recorder Accuracy: ±4˚F (±2.5˚C) over full scale
Ambient Operating Temperature: -22 to +122˚F (-30 to +50˚C)
Response Time: 11 minutes to move 63% of full scale in air moving 5’ per second
Temperature Ranges: (˚F or ˚C depending on chart installed) -14 to +32˚F (-25 to 0˚C),
+4 to +50˚F (-15 to +10˚C), +22 to +68˚F (-5 to +20˚C),
+50 to +96˚F (+10 to +35˚C), +76 to +122˚F (+25 to +50˚C)
Recording Time: 24 hour or 7 day
Power Supply: Single “AA” battery, up to 2 years average life
Resolution: Not less than 1” per +55˚F in 1˚C or 2˚F steps
Mounting: Free standing, wall mounted or suspended
Chart Size: 3” (75mm) DIA
Dimensions: 3.667” x 3.667” x 2.232” (93mm x 93mm x 57mm)
Weight: 0.5 lbs. (227 g)
Includes: Battery, pen and instruction manual