Dickson Industrial SC3 Marine Instruments User Manual


 
Rev. 06/03
Rev. 06/03
Product
Applications &
Useful Features
Product
Specications
Charts &
Accessories
Calibrations Operating
Instructions /
Getting Started
Troubleshooting Warranty/
Factory Service
& Returns
DICKSON
Getting Started
Place chart on recorder
Set time by inserting a coin into chart hub and turning clockwise until the current hour is referenced to the
time index clip. (Time index clip is directly to the right and below the pen tip).
Remove protective pen cap. The chart movement is self-starting and runs continuously. Allow unit to
stabilize in environment for 15 minutes.
Pen Replacement
Slide the used pen cartridge off and slide the new one on. Typical pen life is one year.
Battery Replacement
The battery compartment is located on the back of the recorder. The recorder uses a standard “AAA”
battery for up to two years of battery life.
Insert new battery with the positive end down
Chart Rotation Speed
The unit has a switchable clock, you can change the speed from a 7 day to a 24 hour rotation and from a
24 hour to a 7 day rotation. Make sure the right chart is selected for your rotation. Simply move the switch
located on the back of the unit to the speed that ts your application.