Dometic HTS-EC Marine Sanitation System User Manual


 
10
MODEL 1606
BASE ASSEMBLY
REAR VIEW, VACUUM TOILET
TROUBLESHOOTING GUIDE
VACUUM BREAKER / BOWL
CONNECTION
HOSE
CONNECTION
MODELS 1609, 1648
BASE ASSEMBLY
1. Water will not stay in bowl.
a. Loose clamp ring.
b. Improper seal around flush ball
due to dirt or debris on underside
of ball seal.
c. Worn or damaged seal.
d. Worn or damaged flush ball.
a. Tighten clamp ring adjusting screw.
b. Inspect flush ball and underside
of seal for foreign objects. Clean
under seal if needed (see page 7).
c. Replace seal.
d. Replace flush ball.
Problem Possible Cause Service Instructions
ADJUSTING NUT
FLUSH BALL
SPRING
CARTRIDGE
WATER VALVE ASSEMBLY
TOP VALVE CAP
FILTER SCREEN
WATER
VALVE
SCREWS
VALVE BODY
SHAFT
FLUSH PEDAL
PEDAL
COVER
CLAMP RING
BALL SEAL
ADJUSTING NUT
SPRING
CARTRIDGE
WATER VALVE ASSEMBLY
TOP VALVE CAP
FILTER SCREEN
WATER VALVE SCREWS
VALVE BODY
SHAFT
PEDAL
COVER
CLAMP RING
BALL SEAL
FLUSH BALL
CAM STRAP