Eaton Electrical ETN1000 Marine Battery User Manual


 
Operating conditions In English Description
DC bus voltage is too high High DC Bus
The DC BUS voltage is higher than
expected
DC bus voltage is too low Low DC Bus
The DC BUS voltage is lower than
expected
2.5V reference voltage inside
problem
Ref 2.5V Fault The 2.5V reference inside are abnormal
Output DC sensor abnormal DC Sensor Fault Detection of DC output sensor is abnormal
GFCI detection problem GFCI Failure The GFCI detection circuit is abnormal
System Information
Model display
EATON ETN1000
/ETN2000
Inverter model, xkW inverter
LCD contrast Contrast LCD contrast setting
LCD contrast setting Set Contrast Contrast setting of LCD display
LCD display lock Lock Hold the present display message
Waiting for reconnect to grid Reconnect xxxS
The time that needs to reconnect grid
power
Firmware version Ver. xx.xx F/W version information
Setting Language Set Language Set up of the display language
Edition 1.6E, 2010/06 26