Emerson 3-9008-504 Marine Instruments User Manual


 
OCT 2013 DANIEL™ SERIES 1500 TURBINE METER
MAINTENANCE5-2
5.3 Disassembly Procedures - Internal Components
A. All sizes
1. Before removing the meter from the system the following precautions must be taken:
a. Disconnect all power to the meter.
PERSONAL INJURY AND/OR EQUIPMENT DAMAGE
Disconnect power to the meter.
Failure to disconnect power to the meter could result in serious personal injury and/or damage
to the equipment.
b. Relieve all line pressure.
PERSONAL INJURY AND/OR EQUIPMENT DAMAGE
Relieve pressure at this time.
Failure to relieve line pressure at this time could result in serious personal injury and/or
damage to the equipment.
2. Disconnect conduit connections to the Series 1500 Turbine. (Reference Figure 7-1)
a. Remove screws (item 52) and top cover (item 16) of the UMB.
b. Disconnect conduit connections from terminal board TB1 (assembly item 56).