Fluke 724 Marine Instruments User Manual


 
724
Users Manual
ii
Using Resistance-Temperature Detectors (RTDs) ............................................... 23
Using Source Mode........................................................................................................ 26
Sourcing Electrical Parameters ................................................................................. 26
Simulating Thermocouples........................................................................................ 27
Simulating RTDs........................................................................................................ 27
Setting 0 % and 100 % Output Parameters ................................................................... 30
Stepping and Ramping the Output................................................................................. 30
Manually Stepping the Output................................................................................... 30
Auto Ramping the Output.......................................................................................... 31
Storing and Recalling Setups......................................................................................... 31
Calibrating a Transmitter................................................................................................ 32
Testing an Output Device............................................................................................... 34
Replacing the Batteries.................................................................................................. 35
Replacing the Fuse........................................................................................................ 35
Maintenance................................................................................................................... 36
Cleaning the Calibrator.............................................................................................. 36
Service Center Calibration or Repair......................................................................... 36
Replacement Parts.................................................................................................... 37
Specifications................................................................................................................. 39
DC Voltage Measurement......................................................................................... 39
DC Voltage Source.................................................................................................... 39
DC mA Measurement................................................................................................ 39
Ohms Measurement.................................................................................................. 40
Ohms Source............................................................................................................. 40
Millivolt Measurement and Source*........................................................................... 41
Temperature, Thermocouples................................................................................... 41
Temperature, RTD Ranges, and Accuracies (ITS-90)............................................... 42
Loop Power Supply ................................................................................................... 43