Furuno 10n Fish Finder User Manual


 
11
Thru-hull mount water temperature sensor T-02MSB, T-03MSB
Select a suitable mounting location considering the following points:
Select a mid-boat flat position. The sensor does not have to be installed perfectly
perpendicular. However, the location should not be such that the transducer may be
damaged when the boat is dry-docked.
Locate away from equipment which gives off heat.
Locate away from drain pipes.
Select a location where vibration is minimal.
Sensor
cable
Locknut
Coat with
sealant.
Plate thickness
within 25 mm
Coat with
sealant.
φ21 mm
φ25 mm
Washer
Gasket
Locknut
Locknut
Washer
Gasket
Holder Guide
Sensor Holder
T-02MSB T-03MSB
Mounting procedure
1. Drill a hole of 21 mm in diameter in
the mounting location.
2. Pass the sensor cable through the
hole.
3. Pass gasket, washer and locknut
onto cable in that order.
4. Coat the sensor flange with high
quality sealant and then fasten the
sensor with the locknut.
(Torque: max. 59N·m)
5. Launch the boat to check for water
leakage around the sensor.
Mounting procedure
1. Drill a hole of 25 mm in diameter in the mounting
location.
2. Coat holder guide with high quality sealant, and
pass gasket, washer and locknut onto holder
guide in that order and then tighten the locknut.
3. Set the sensor holder to the holder guide from
inside the boat and then tighten the locknut.
4. Launch the boat to check for water leakage
around the sensor.
Figure 1-15 Assembling thru-hull water temperature sensor T-02MSB, T-03MSB