3-10
STC CURVE
The default STC curve can be maintained in most cases. If necessary the STC curve can
be changed as follows:
1. Open the RADAR SETUP menu and select STC CURVE.
2. Press the A: EDIT soft key to show the setting window.
E RETURN
NARROW
NORMAL
WIDE
STC CURVE
STC curve setting window
3. Select STC curve;
NARROW: The effective range of the [A/C SEA] adjustment is relatively short.
NORMAL: Between NARROW and WIDE.
WIDE: The effective range of the [A/C SEA] adjustment is relatively long.
4. Press the E: RETURN soft key to finish.
HEADING DATA
Select the heading reference, MAGNETIC or TRUE. Select MAGNETIC when connecting
with a magnetic compass, or select TRUE when connecting with a true heading compass.
For your reference, when connecting with the FURUNO Satellite Compass SC-60/120 or
Integrated Heading Sensor PG-1000, set the heading data as in the table shown below.
Model Setting of HEADING DATA
with L/L data TRUE
PG-1000
w/o L/L data MAGNETIC
SC-60/120 TRUE
1. Open the RADAR SETUP menu and then select HEADING DATA.
2. Press the A: EDIT soft key to show the setting window.
HEADING DATA
MAGNETIC
TRUE
Heading data setting window
3. Select MAGNETIC or TRUE.
4. Press the C: ENTER soft key.