Furuno 1823C-BB Marine GPS System User Manual


 
3-18
3.7 Remote System Setting
MODEL 1800C/1900C-BB series NavNet system can be used as a remote system for
FAR/FR-2805, 2105 series, etc., by using optional cable assy MJ-B24LPF0008-100 (10 m),
200 (20 m) or 300 (30 m).
To use the processor unit as a remote system, do the following:
1. Open the RADAR SETUP menu.
2. Use the trackball or [ENTER] knob to select MONITOR MODE, and press the A: EDIT
soft key.
3. Select ON.
4. Turn the MBS function off at the main radar.
5. Turn the VIDEO ADJUST on at the NavNet processor unit.
6. Select “H” at the ANTENNA TYPE on the RADAR SETUP menu.
Note: TX blanking function is not available when the MONITOR MODE is ON. To set a TX
blanking sector, select OFF from MONITOR MODE on the NavNet equipment, and then set
the sector same as the main radar. Finally, set MONITOR MODE to ON.
When the MONITOR MODE is ON, the following functions are not available.
•Tuning (auto/manual, on the RADAR SETUP menu)
•Antenna rotation (RADAR SETUP menu)
•TX blanking sector (RADAR DISPLAY SETUP menu)
•Watchman (RADAR DISPLAY SETUP menu)
•Pulse select (Soft key)