Furuno 611 Marine Instruments User Manual


 
2. BASIC OPERATION
2-2
2.2 Turning On/Off
Press the [STBY/POWER] key to turn the unit on. (For PG-500, see Note 2
shown below.) A beep sounds and the equipment proceeds in the sequence
shown below, showing product information and startup test results. The startup
test checks the ROM, RAM, backed up data and communication between the
control unit and processor unit, and also checks for the presence of heading
from the sensor and rudder angle information from the rudder angle indicator. If
NG appears, an appropriate message will also appear on the screen. If NG is
shown, contact your dealer for advice.
START UP TEST
PROCESSOR OK 6454002-**.**
CONTROLLER OK 6454003-**.**
ROM RAM BACKUP
PROCESSOR UNIT OK OK OK
CONTROLLER OK OK OK
HEADING SENSOR OK 359.9
-------------------------------------------
RRU OK P12.3
CONTROLLER ID 1
AUTO PILOT
NAVPILOT-511*
FURUNO ELECTRIC CO., LTD
**.** : Program version no.
(520)
Navpilot-520: 645004-**.**
Navpilot-611: 645005-**.**
*For Navpilot-611, "NAVPILOT" appears.
Startup sequence
After the startup test is completed, “STBY” appears on the screen. This means
that the equipment may now be operated manually.
Note 1: The first time you turn on the power, you are asked to select Normal,
Installation or Simulation mode. Rotate the course control knob to select
the appropriate mode, and then press it.
Note 2: When the Integrated Heading Sensor PG-500 is connected, turn on the
NAVpilot-511/520/611 and wait four minutes before leaving port in order
to allow time for the PG-500 heading data to stabilize.
Note 3: The example screens shown in this manual may not match the screens
you see on your display. The screen you see depends on your system
configuration and equipment settings.
Turning the power off
Press and hold down the [STBY/POWER] key until the screen goes blank.