Furuno FAR-2157-D Marine RADAR User Manual


 
2-7
8. Fabricate the power cable as shown below.
How to fabricate power cable TYPCY-2.5
9. In the order shown in figure below, pass the gland nut, flat washers (3 pcs.) and gasket onto
the power cable.
10.As shown in the figure below, fold back the armor onto flat washer (2) and insert remaining
armor through flat washer (3). Cut off the part of the armor that protrudes past the flat washers
(2) and (3).
Passing flat washer, etc. onto power cable
11.Pass the power cable through its cable gland and tighten gland nut.
12.Connect wiring to the terminal TB901, referring to the interconnection diagram.
13.Close the cover that protects pcb 03P9435.
14.Seal the cable gland for the power cable and HV cable with putty.
25 mm
5 mm
FV2-4
Sheath
Armor
Vinyl sheath
Conductor
S = 2.50 mm
2
φ = 2.01 mm
Armor
Sheath
SECTIONAL VIEW
500 mm
(1)
Flat washer
(2) (3)
Cut off armor that
protrudes past washer.
Gasket
Power cable
Gland nut
High voltage is present at the No. 6 pin
of TB901. Miswiring at this pin can
damage the antenna unit.
CAUTION
CAUTION