Furuno FAR-2157-D Marine RADAR User Manual


 
4-3
5. Connect J602 (attached at step 3) to the GYRO CONVERTER board with two VH connector
assemblies 03-2089 (3P) and 03-2090 (5P).
Connecting connector assemblies inside processor unit
6. Confirm gyrocompass specifications and set up the DIP switches and jumper wires on the
GYRO CONVERTER board according to gyrocompass connected:
Setting jumper wires and DIP switches by gyrocompass specifications: page 4-6
Setting jumper wires and DIP switches by make and model of gyrocompass: page 4-7
Location of jumper wires and DIP switches: page 4-8
1
1
4
1
1
2
1
3
1
2
1
3
1
1
2
1
5
1
7
XH-PH connector assy.
03-2088 (6-14P)
NH connector assy.
03-2091 (5P)
VH connector assy.
03-2089 (5P)
VH connector assy.
03-2090 (3P)
J1
P1
J603
P603
GYRO CONVERTER
64P1106A
TB
03P9342
P608
J7
J4
J5
P5
P4
P7
J602
To P608
To J602
1
2
2
P608
1
2
34
BRN
RED
ORG
YEL
1
Connection for P608
2
Connection for J602
17 23456
BRN
RED
ORG
YEL
GRN
BLU
PPL
J602
Procedure
1. Twist core.
2. Press terminal opener downward.
3. Insert wire to hole.
4. Remove terminal opener.
5. Pull wire to confirm that it is secure.
Terminal opener
Wiring WAGO connector
WAGO connector
Wire
Twist
Press downward.
From J5
From J4