Furuno FAR-3330SW Marine RADAR User Manual


 
FURUNO
FAR-32x0/33x0 SERIES
SP - 3 E3616S01C-M
4.4 Effective radar diameter 264.6 mm (MU-190), 335.2 mm (MU-231)
4.5 Visible distance 1.02 m nominal
5 INTERFACE
5.1 Processor unit (EC-3000)
Serial I/O 7 ports (IEC61162-1/2: 2 ports, IEC61162-1: 5 ports)
Input ABK, ACK, ACM, ACN, ALR, CUR, DBT, DPT, DTM, GGA, GLL,
GNS, HBT, HDT, MTW, MWV, RMC, THS, VBW, VDM, VDO,
VDR, VHW, VTG, ZDA
Output ABM, ACK, ALC, ALF, ALR, ARC, BBM, EVE, HBT, OSD, RSD,
TLB, TTD, TTM, VSD
Digital input 1 channel: contact signal, 100 ohm max. or 24VDC input
Alarm output 6 channels: contact signal, load current 250 mA
Normal close: 2, Normal open: 2, System fail: 1, Power fail: 1
DVI output 2 ports: DVI-D (DVI 1/2), 1 port: DVI-I or RGB (DVI 3)
USB 4 ports (3 ports for control units)
LAN 2 ports: Ethernet 1000Base-T for network equipment and
sensor adapter
5.2 Sensor adapter (option)
MC-3000S (serial) 8 ports: I/O, IEC61162-1/2: 4 ports, IEC61162-1: 4 ports
MC-3010A (analog) 3 ports: Input, -10 to +10 V, 0 to 10 V or 4 to 20 mA
MC-3020D (digital-in) 3 ports: relay contact, logics set from program
MC-3030D (digital-out) 3 ports: relay contact, normal open and normal close available
6 POWER SUPPLY
6.1 Power supply unit (w/ antenna and transceiver unit)
FAR-3210/3310 (X-band, 12 kW)
PSU-014 (24rpm) 100-230 VAC: 2.0-1.0 A, 1 phase, 50-60 Hz
PSU-014 (42rpm) 100-230 VAC: 2.4-1.1 A, 1 phase, 50-60 Hz
FAR-3220/3320/3320W (X-band, 25 kW)
PSU-014 (24rpm) 100-230 VAC: 2.4-1.2 A, 1 phase, 50-60 Hz
PSU-014 (42rpm) 100-230 VAC: 3.7-1.6 A, 1 phase, 50-60 Hz
FAR-3230S/3330S/3330SW (S-band, magnetron)
PSU-014 (24rpm) 100-230 VAC: 3.7-1.6 A, 1 phase, 50-60 Hz
PSU-015 (42rpm) 100-230 VAC: 6.4-2.7 A, 1 phase, 50-60 Hz
FAR-3230S-SSD/3330S-SSD (S-band, SSD)
PSU-016 (24rpm) 100-230 VAC: 2.8-1.4 A, 1 phase, 50-60 Hz
PSU-018 (42rpm) 100-230 VAC: 5.6-2.5 A, 1 phase, 50-60 Hz
6.2 Processor unit (EC-3000) 100-115/220-230 VAC: 1.5/0.7 A, 1 phase, 50-60 Hz
6.3 Monitor unit
MU-190 100-230 VAC: 0.7-0.4 A, 1 phase, 50-60 Hz
MU-231 100-230 VAC: 1.0-0.6 A, 1 phase, 50-60 Hz
6.4 Sensor adapter (option) 24 VDC: 1.4 A (for 11 units), input to MC-3000S, the sources of
other sensor adapters are fed from MC-3000S