Furuno FMD-3200 Marine GPS System User Manual


 
ā–²
Multifunction display capability, featuring ECDIS,
Conning Information Display, Radar/Chart Radar* and
Alert Management System**
ā–²
Intuitive new user interface offers fast, precise route
planning, monitoring and navigation data management
Navigation sensors can be directly interfaced with the ECDIS processorā€™s 8 serial I/O ports.
Sensor adapters are required under the following conditions:
ā€¢ the sensor data is to be shared amongst multiple networked ECDIS and Radar systems,
ā€¢ the number of sensors interfaced is more than the number of the ports the processor has (8 serial I/O ports, 1 digital IN and 6 digital OUT), and/or
ā€¢ the networked sensors include analog sensors.
In order to integrate onboard sensors into the navigation network, the sensor adapter may be interfaced with the switching hub
HUB-100 from which distribution of the sensor data throughout the network is possible.
Alternatively, multiple sensor adapters may be interfaced via Ethernet to integrate onboard sensors for use in the shipboard network.
* a radar sensor needs to be integrated in the network.
** Radar and Alert Management System display capabilities are to be implemented as
software upgrade. (option)
* Software update on FAR-21x7/FAR-28x7 series might be necessary depending on the
program number.
ā–²
Interface with existing FAR-21x7/FAR-28x7 series Radar
for Radar overlay, target track info, route and waypoint
exchange via Ethernet
ā–²
Complies with the following IMO and IEC regulations:
ā€¢ IMO MSC.232(82)
ā€¢ IMO A.694(17)
ā€¢ IEC 61174 Ed. 3
ā€¢ IEC 61162-1 Ed. 4
ā€¢ IEC 61162-2 Ed. 1
ā€¢ IEC 62288
ā–²
Compatible cartography
ā€¢ IHO/S-57 Edition 3 vector chart
(IHO S-63 data protection scheme)
惻
Admiralty Vector Chart Service by UKHO
惻
C-MAP ENC
惻
Jeppesen Primar ECDIS Service
ā€¢ ARCS raster chart
ā€¢ C-MAP Professional+*
*C-MAP Professional+ is a private chart, hence not construed as replacement for paper chart.
ā–²
Interface with Jeppesen Dynamic Licensing Service
available
ā–²
Compatibility with Admiralty Information Overlay
(AIO) for further navigation safety
Electronic Navigational Chart Raster Navigational Chart
ā–²
Instantaneous chart redraw delivered by FURUNOā€™s
advanced chart drawing engine, making redraw latency
a thing of the past
Instantaneous chart redraw
ā–²
Ease of installation and maintenance thanks to simpliī€Ÿed cabling in the sensor-to-ECDIS/Radar interface
delivered by common sensor adapter
Sensor Adapter acts as central medium to gather all the sensor data and collectively
feed it to all FMD-3200/3300 ECDIS and FAR-3000 Chart Radar in the system. Since
sensor adapter can be extended to cover all the sensors within the system, individual
cablings in the sensor-to-ECDIS/Radar interface can be greatly reduced.
Additional AIO layer includes all Admiralty Temporary and Preliminary
Notices to Mariners as well as additional ENC Preliminary Notices to
Mariners, i.e., reported navigational hazards that have been incorporated
into paper chart but have yet to be included in ENCs. The service is free
of charge as part of Admiralty Vector Chart Service (AVCS) by UKHO.
Models:
FMD-3200/3300
Fast, intuitive route planning and
navigation monitoring
Fast, intuitive route planning and
navigation monitoring
Models: FMD-3200
(
with 19" LCD
)
/ FMD-3300
(
with 23.1" LCD
)
Radar Conning Information Display
ECDIS
System diagram
for the current
Model
Model:
FEA-2x07
System diagram
for the new Model
HUB-3000
Gyro 1 Gyro 2GPS 1 GPS 2HCS Speed log
Anemometer
Nav. E.S. AIS
Sensor AdapterSensor Adapter
HUB-100 HUB-100
HUB-100
HUB-100
LAN Adapter
B Adapter
Gyro 1 Gyro 2GPS 1 GPS 2HCS Speed log
Anemometer
Nav. E.S. AIS
B Adapter
LAN Adapter
HUB-100
AIO data layer displayed
Chart object window
Place the cursor on the AIO object
and right-click to open the contextual
menu. Select ā€œObject INFOā€ to open
the chart object window.
The full text of the Notice to Mariners
as well as associated diagrams can
be displayed subsequently.
On the chart object window,
select the AIO object and click
"OK" to view the details.
Sensor Adapter
MC-3000S/3010A/3020D/3030D
ECDIS Control Unit
RCU-024
3.3 kg 7.3 lb
Trackball Control Unit
RCU-026
1.5 kg 3.3 lb
Processor Unit
EC-3000
14 kg 30.9 lb
Switching Hub
HUB-100
1.5 kg 3.31 lb
Intelligent Hub
HUB-3000
1.5 kg 3.31 lb
270 10.63"
255 10.03"
242 9.53"
115 4.53"
162 6.38"
15 0.59"
145 5.71"
45
1.77"
47 1.85"
4-Ćø5
Fixing Hole
Sensor Adapter
Serial
MC-3000S
1.5 kg 3.3 lb
Analog
MC-3010A
0.8 kg 1.8 lb
Digital In
MC-3020D
0.8 kg 1.76 lb
Digital Out
MC-3030D
0.8 kg 1.76 lb
Monitor Unit
MU-190 8.8 kg 19.4 lb MU-231 12.8 kg 28.2 lb
450 17.7"
110 4.3"
389 15.3"
397 15.6"
448 17.6"
489 19.3"
4-Ƙ18
Cutout for ī€Ÿush mount
471 18.5"
554 21.8"
592 23.3"
112
4.4"
484.9 19"
553 21.8"
Cutout for ī€Ÿush mount
IMO ECDIS Model Course 1.27
(Generic ECDIS training)
FURUNO INSTC
NavSkillsā„¢ facilities
FURUNOā€™s provision of thoroughgoing ECDIS training programs
Proper training is required to ensure an efī€Ÿcient and safe operation of vessels as well as to
optimize the advantages of having ECDIS onboard. Advantages include less time spent on chart
management and voyage planning and increased safety through the proper setup and operation of
the ECDIS, which can remarkably reduce the risk of groundings, etc. Training comes in many
forms and the crew should undergo both generic training to get full understanding of the ECDIS as
a concept, the rules governing ECDIS and the inī€žuences on the bridge operation. Crews should
also receive ECDIS familiarization training, which helps the operator familiarize themselves with
the speciī€Ÿc ECDIS onboard the vessel. FURUNO offers the ECDIS trainings through its INS
Training Centers (INSTC in Copenhagen and Singapore) as well as other training facilities signed
up as NavSkillsā„¢ training facilities. NavSkillsā„¢ training solution is the service and support for
maritime training centers and shipowners, who are looking to establish their own training facilities
in full compliance with STCW and IMO standards. NavSkillsā„¢ training package includes provision
of training simulators, provision and update on course materials and curriculum, training for
instructors, certiī€Ÿcation of the trainees by INSTC and much more.
STCW requires that all masters and ofī€Ÿcers in charge of a navigational watch (Ofī€Ÿcer of the
Watch: OOW) on a ship ī€Ÿtted with ECDIS shall have completed a generic ECDIS course and
hold an ECDIS certiī€Ÿcate in accordance with IMO model course 1.27.
This ECDIS training provides the trainees with knowledge of the ECDIS as a system,
its operation, electronic chart materials and practical navigation. Also, the course includes
terms and conditions for implementing paperless navigation. The training course focuses upon
many advantages and safety features obtained by operating ECDIS. The limitations of ECDIS
are taught throughout this training course.
This training concludes with 3 compulsory tests, and, if passed, a certiī€Ÿcate is issued, which
conī€Ÿrms the trainees' successful completion of the generic ECDIS training in accordance with
IMO Model Course 1.27, reviewed by DNV SeaSkillā„¢.
The course is available at INSTC Denmark.
FURUNO ECDIS familiarization training course
FURUNO ECDIS familiarization training provides trainees with speciī€Ÿc knowledge about
functionality and effective use of FURUNO ECDIS for navigation.
The training covers the following aspects of FURUNO ECDIS operation:
ā€¢ Familiarization with available functions ā€¢ familiarization with the menu structure
ā€¢ Display setup ā€¢ Setting safety value ā€¢ Route planning ā€¢ Route monitoring
ā€¢ Recognition of alarm and malfunction indicators and the actions to be taken
ā€¢ Changing over to backup systems ā€¢ Loading and updating of charts and licenses
ā€¢ Updating software
The training concludes with a compulsory test. Upon successful completion of the test, the
navigators are issued with a certiī€Ÿcate that conī€Ÿrms the successful completion of the FURUNO
ECDIS familiarization training course. This training complies with the STCW and ISM Codes,
audited and certiī€Ÿed by ClassNK (INSTC Denmark and INSTC Singapore).
The course is available at INSTC in Denmark and Singapore. Also, NavSkillsā„¢ training facilities
around the globe offers the range of ECDIS training services. For details of locations and training
availability, please visit www. navskills.com.
ā–²
Contact Info
FURUNO INS Training Center Denmark
Hammerholmen 44-48, DK-2650 Hvidovre,
Denmark
Phone: +45 36 77 40 12
E-mail: instc-denmark@furuno.com
FURUNO INS Training Center Singapore
No. 17, Loyang Lane, Singapore 508917
Phone: +65 6745 8472
E-mail: instc-singapore@furuno.com
Please ī€Ÿnd the contact information as well as the training service availability of each of the NavSkillsā„¢ training
facilities at the FURUNO training service web site: www.navskills.com where you can also ī€Ÿnd the detailed course
descriptions as well as other practical information.
Click
>>>
to open
Click
<<<
to retract
1
MFD operating mode selector
1
Items on the lower part of the InstantAccess bar:
3
Other buttons on the Status bar
Click to enter Man Overboard mark on the chart.
Click to take a screenshot.
Click to undo/redo the past actions.
By clicking this button, the MFD
operating mode selector will open.
2
Operation Mode
These three buttons give quick access
to the three ECDIS operation modes:
ā€œMonitor modeā€, ā€œChart Maintenance
modeā€ and ā€œPlan modeā€. Once an
operation mode is selected, the upper
part of the InstantAccess bar will
change accordingly, providing quick
access to the tasks specific to each of
the ECDIS operation modes.
Click to play back log.
Shows only the chart,
while long-pressed by the
left-click key.
Click to restore the IMO
standard display.
Click to set priority order of
chart to be displayed.
Click to select IMO chart
display setting: IMO BASE,
IMO STD or IMO-ALL.
Click to display the
operatorā€™s manual, ECDIS
program number and
system information.
Click to select, manage and
set the user profile.
Status bar
InstantAccess bar
When clicking on the InstantAccess bar, the InstantAccess bar will retract to the edge of the screen.
By clicking the hidden bar at the edge of the screen, the InstantAccess bar will come back in.
The upper part of the InstantAccess bar contains the list of available tasks/functions speciī€žc to each of the ECDIS
operation modes selected, hence providing quick access to the needed tasks/functions to be performed. While the
menu items of the upper part of the InstantAccess bar change according to the mode selected, the lower part of the
InstantAccess bar is static for all modes, except for ā€œMini Conningā€, which is only available in the ā€œMonitor modeā€
and ā€œPlan modeā€.
Click to display Admiralty Information Overlay.
Click to show and hide the mini conning display, only
available in the ā€œMonitor modeā€ and ā€œPlan modeā€.
Click to view various data about the chart
currently displayed, the contents of which
depend upon the type of chart displayed.
Click to view overview of ECDIS
chart symbols.
Click to open a chart viewing date
setup window.
Click to enter setting windows for chart/symbol display as well as chart alert.
Click to split the screen in two (two-way split screen).
Click to activate on-screen keyboard.
Click to record user/position events to the event log as well as to access
various logs to observe, including: navigation logs (details log, voyage log
and chart usage log), target log and alert log.
Click to summon display brilliance level adjustment window where the
brilliance level can be adjusted either manually (by gauge) or
automatically (by clicking the automatic brilliance adjustment button, next
to the brilliance gauge).
Click to select a color palette (color and brilliance set of the screen
presentation) to match the ambient lighting conditions.
31 2
1
426 16.77"
396 15.59"
45 1.77"150 5.9" 150 5.9"
360 14.17"
3-Ćø8
Fixing hole
15 0.59"
153 6.02"
150 5.9"
no less than 150 5.91" no less than 100 3.94"
42 1.65"
33
1.3"
172 6.77"
153 6.02"
133 4.06"
4-Ćø5
Fixing hole
324 12.76"
336 12.23"
350 13.79"
220 8.66"
235.5 9.27"
150 5.91"64 2.52"
180 7.09"
4-Ćø5
Fixing
Hole
48 1.88"
41 1.61"
100 3.94"
60 2.36"
235.5 9.25"
150 5.91" 64 2.51"
4-Ćø5
Fixing
Hole
48 1.88"
41 1.61"
48 1.88"
41 1.61"
no less than 150 5.91"
100 3.94"
4-Ćø5
Fixing
Hole
60 2.36"
150 5.91"64 2.52"
235.5 9.25"
48 1.88"
41 1.61"
no less than 150 5.91"
100 3.94"
4-Ćø5
Fixing
Hole
60 2.36"
150 5.91"64 2.52"
235.5 9.25"
120 4.72"
180 7.09"
no less than 70 2.76"
Max 70
2.76"
170 6.69"
120 4.72"
110 4.33"
180 7.09"
398 15.67"
55
2.17"
388 15.28"
398 15.67"
170 6.69"
180 7.09"
38
1.5"
10 to 20
0.39" to 0.79"
no less than
72 2.83"
339 13.35"32 1.26"
180 7.09"
18 0.71"
216 8.5"