Graco 16P957 Marine Sanitation System User Manual


 
Repair
3A2798D 17
Repair
Disconnect Pump from Platen
1. Loosen two thumb screws (412) from platen.
2. Carefully pull pump away to prevent damage to
pump inlet. Remove adapter (421) and o-ring (406)
from platen adapter (421).
Connect Platen to Pump
1. Apply grease to o-ring (406) then install the o-ring
on platen adapter (421). See F
IG
. 15.
2. Apply pipe sealant to pump inlet thread then thread
onto adapter (421).
3. Loosen thumb screws (412) then carefully lower
pump onto platen.
4. Tighten thumb screws (412) to secure platen to
adapter.
Remove Wipers
See Remove and Reinstall Wipers on page 13.
Install Wipers
See Remove and Reinstall Wipers on page 13.
F
IG
. 15
406
421
412
ti20254b