3A2798D 25
Pumpline
--- Not for sale.
201,
7
Torque to 50-60 ft-lb (68-81 N•m).
Torque together to 145-155 ft-lb (196-210 N•m).
Apply sealant.
Insert lanyard from locking pin onto tie rod (2).
Apply thread lubricant to threads, o-rings, and seals. Do not
apply to rod adapter (216) or rod (229).
Push in de-ice control (15) fully. Symbols must be upright.
1
2
3
4
5
7
215
202
229
216
203
204
207
206
205
1
2 3
2 3
4
1
212
ti20241a
Ref Part Description
Qty
201 N65DN0 MOTOR, 6500
1
202 --- ROD, tie
3
203 197340 COVER, coupler
1
204 244819 COUPLING, assembly
1
205 L180C7 LOWER, Xtreme
1
206 101712 NUT, lock
3
207 244820 CLIP, hairpin; with lanyard
1
208 --- SEALANT, anaerobic
1
212 --- LABEL, Xtreme PFP
1
214 --- LUBRICANT, thread
1
215 15J277 CONTROL, de-ice
1
216 15H392 ADAPTER, rod, Xtreme
1
229 --- ROD, adapter
1