Graco 16T311 Marine Sanitation System User Manual


 
Installation
3A2798D 9
Connect Mix Line and Gun
NOTE: Kit 24P832 includes items 5, 6, and 11-16 in F
IG
.
6.
1.
If installing mix line and gun kit 24P832,
install
nipple (5), check valve (6), and second nipple (5)
onto the pump outlet as shown in F
IG
. 6.
2. Connect the supplied 3/4 in. hose (11) to the
nipple (5). See F
IG
. 6.
3. Use reducing nipple (12) to connect the supplied
1/2 in. whip hose (13) to the 3/4 in. hose (11).
4. Use nipple (14) to connect gun swivel (15) to whip
hose (13).
5. Connect gun (16) to gun swivel (15).
Mechanical Setup
1. Fill displacement pump wet cup 2/3 full with Graco
Throat Seal Liquid (TSL
).
2. Back-off air regulators to their full counterclockwise
position and close all shutoff valves.
3. Connect air line from an air source to the system air
inlet. See F
IG
. 1. Use a supply hose capable of
meeting the required flow.
NOTE: Quick disconnects restrict flow for large air
motors.
Attach Drum Stops
This unit is shipped with drum stops in place to help
position the drum on the ram. For replacement parts,
order Kit 255477. The kit includes 2 each of capscrews
(FA), lock washers (not shown), and drum stops (FB).
1. Locate the correct set of mounting holes on the ram
base.
2. Using the capscrews (FA) and lock washers (not
shown), attach the drum stops (FB) to the ram base.
NOTE: Only use the 5 gallon drum stop position shown
in F
IG
. 8.
F
IG
. 6
ti20229b
5
11
12
13
16
15
5
14
6
F
IG
. 7
F
IG
. 8: Ram Base
FA
FB
ti20248b
5 gal (20 L)