33. Hold the right clevis stationary with a 1 in. open-end
wrench and, by turning the baffle jam nut with a 1 in.
torque-wrench, torque the right clevis to 15 ft-lb
(20 N•m) against the activator plate.
34. Hold the left clevis stationary with a 1 in. wrench and
break the baffle jam nut loose from the hydraulic pis-
ton shaft.
35. Hold the baffle jam nut stationary and rotate the left
clevis so the cross-holes form a horizontal line,
keeping one to two threads between the clevis head
and the nut.
CAUTION
In the following step, do not over torque.
In the following step, do not unscrew the left clevis
more than necessary.
1
Hold stationary.
Rotate to torque the right clevis.
1
2
2
TI11285a
1
Hold stationary.
Rotate to break baffle jam nut loose from piston shaft.
1
2
2
TI11286a
Hold baffle jam nut stationary.
Rotate to position cross-holes in a horizontal line.
1
2
1
2
TI11287a