Technical Data
312796R 25
Technical Data
* Sound power at 70 psi (0.48 MPa, 4.8 bar), 20 cpm. Sound power measured per ISO-9614-2.
** Sound pressure was tested 3.28 feet (1 m) from equipment.
Maximum air inlet pressure . . . . . . . . . . . . . . . . . . . . . . . 100 psi (0.7 MPa, 7.0 bar)
Stroke length (all except M34xxx) . . . . . . . . . . . . . . . . . . 2.5 in.
Stroke length (M34xxx only) . . . . . . . . . . . . . . . . . . . . . . 4.75 in.
Air inlet size
M02xxx – M04xxx . . . . . . . . . . . . . . . . . . . . . . . .
M07xxx – M34xxx . . . . . . . . . . . . . . . . . . . . . . . .
1/4 in.
1/2 in.
Maximum motor speed. . . . . . . . . . . . . . . . . . . . . . . . . . .
(Do not exceed maximum recommended speed of fluid
pump, to prevent premature pump wear.)
60 cycles per minute
Sound data
M02xxx Air Motor
Sound power* . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sound pressure** . . . . . . . . . . . . . . . . . . . . . . . .
82.8 dBA
72.9 dBA
M04xxx Air Motor
Sound power* . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sound pressure** . . . . . . . . . . . . . . . . . . . . . . . .
83.4 dBA
73.5 dBA
M07xxx and M12xxx Air Motor
Sound power* . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sound pressure** . . . . . . . . . . . . . . . . . . . . . . . .
80.1 dBA
70.2 dBA
M18xxx and M34xxx Air Motor
Sound power* . . . . . . . . . . . . . . . . . . . . . . . . . . .
Sound pressure** . . . . . . . . . . . . . . . . . . . . . . . .
78.8 dBA
68.9 dBA