Graco Inc. 218-946 Marine Instruments User Manual


 
2307-713
WARNING
INSTRUCTIONS
EQUIPMENT MISUSE HAZARD
Equipment
misuse can cause the eq
uipment to rupture or malfunction and result in serious injury
.
D
Do not modify the tube or roller frame or use parts not designed for this equipment.
D
If the adjustable extension tube starts to extend during use, stop rolling immediately and engage
the gun safety latch. Check that the locknut on the tube is tight. If the locknut is tight, the tube or
the roller is clogged; follow the Pressure Relief Procedure on page 3 and flush throughly
.
D
Use the adjustable extenstion tube only with the roller frame described in this manual. This is not
an airless gun extension (pole gun).
FIRE AND EXPLOSION HAZARD
Improper
grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re
-
sult in a fire or explosion and serious injury
.
D
Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid
being applied.
D
Keep the application area free of debris, including solvent, rags, and gasoline.
ELECTROCUTION HAZARD
Avoid
contact with power lines. Contact with power lines could cause serious injury
, including burns or
electrocution.
D
Follow all grounding instructions in your separate pump and paint gun instruction manual.
D
Comply with all local, state, and national fire, electrical, and safety regulations.
Adjustable Extension Tubes
218–775
18–36 in. (0.45–0.9 m)
218–776
3–6 ft (0.9–1.8 m)
218–777
6–12 ft (1.8–3.7 m)
Fig. 1
05882
Tube
Ring
Washer
Seal
Lips of seal must face into tube; grease
before assembly; do not damage lips
Handle
Screw
Apply Loctite
Includes replaceable item 108–163, shaft seal.
Note:
Always flush the extension tube as
instructed in
Flushing
on page 3.
W
etted parts: Stainless Steel, Polyurethane,
Plated Steel