Graco Inc. 218-946 Marine Instruments User Manual


 
4307-713
WARNING
INJECTION
HAZARD
Keep your hands and body away form
the roller frame when flushing. High
pressure fluid emitted from the holes in
the frame could cause an injection injury
.
5.
Point the extension tube and roller frame
away from yourself or any other person.
Then turn on the pump and flush the sys
-
tem thoroughly as described in your sepa
-
rate pump instruction manual, using the
lowest pressure possible. While flushing,
loosen the extension tube locknut and
pump the tube in and out several times.
6.
Shut of
f the pump and follow the
PRES-
SURE RELIEF PROCEDURE W
ARNING
on page 3.
7.
Never leave water in the pump, gun or
extension tube: doing so will cause corro
-
sion.
After flushing with water
, flush again
with solvent or mineral spirits in the sys
-
tem. Retract the extension tube before
storing it.
8.
Clean the roller cover thoroughly before
storing it.
Model 218–625
Includes
items 1–5
Ref.
No.
Part No.
Description Qty.
1 218–935
FRAME, roller
See manual 307–755 for parts
1
2
218–775
EXTENSION TUBE, 18–36”
(460–920 mm) 1
3
239–533
ADAPTER 45
_
, 1/4 npt(m) x 7/8
UNF(F) 1
4 166–969 GASKET 1
5 107–590
COVER, 1/2” nap
1
Fig. 2
05883
1
5
2
34
Sales
Offices:
Atlanta, Chicago, Detroit, Los Angeles
Foreign Offices:
Belgium, Canada, England, Korea, Switzerland, France, Germany
, Hong Kong, Japan
http://www.graco.com
GRACO INC. P.O. BOX 1441
MINNEAPOLIS, MN
55440–1441
PRINTED
IN U.S.A. 307–713 February 1985, Revised January 1998