Ingersoll-Rand 650295 Marine Sanitation System User Manual


 
OPERAT
OR’S MANUAL
650295
RELEASED:
6–27–95
(REV
. A) IPP
INCLUDING: OPERATION, INSTALLATION & MAINTENANCE
PUMP
SYSTEM
ALSOINCLUDEMANUALS:650691-X PUMP, 651616-XTWO POST LIFT/RAM & 65940AIR MANIFOLD
23:1
RA
TIO
6” AIR MOTOR
6” STROKE
650295
READ THIS MANUAL CAREFULL
Y BEFORE INST
ALLING,
OPERA
TING OR SER
VICING THIS EQUIPMENT
.
CARBON STEEL
THE
ARO CORPORA
TION
D
ONE ARO CENTER
D
BR
Y
AN, OHIO 43506–0151
E1995
THE ARO CORPORA
TION
D PRINTED IN U.S.A.
&
(419) 636–4242
D
F
AX (419) 636–21
15
1
2
3
Control Panel
(See Page 2)
Material
Outlet
FIGURE 1
4
F033
SERVICE KITS
Use only genuine ARO replacement parts to assure compatible
pressure rating and longest service life.
61355 for repair of Air Motor Section.
637071-XXX for repair of Lower Pump 66243-X.
GENERAL
DESCRIPTION
WARNING DO NOT EXCEED MAXIMUM OPERATING
PRESSURE OF4,215 P.S.I. (294 BAR) AT 150 P.S.I. (10.4 BAR)
AIR INLET PRESSURE.
WARNING REFER TO GENERAL INFORMATION SHEET
FOR ADDITIONAL SAFETY PRECAUTIONS AND IMPORĆ
TANT INFORMATION.
By delivering a smooth, continuous bead of the proper size, an ARO
system helps the operator maintain both his production rate and proĆ
duce quality standards. Maintained quality standards assures that the
material benefitsare realized. To further maximize operatorproduction
time, the AROSystem has a built-in lift/ram feature for quick and easy
drum changeover.
ARO Systems are totally enclosed, sealing the material in the system
from air and moisture, preventing premature cure-out of the material.
This allows for either continuous or intermittent use of the system and
reduces the need for daily system clean-up.
Built-in liftcapability allowsfor quick drumchangeover and easy lifting
of pump assembly from container.
The 23:1 ratio is an expression of the relationship between the effecĆ
tive air motor area and the effective lower pump area. When 150 PSI
(10 bar)of airpressure issupplied tothe airmotor,thelowerpumparea
will develop a maximum of 4,215 PSI (294 bar) of fluid pressure (at no
flow) as the fluid control is opened, the flow rate will increase asthe air
motor cycle rate increases to keep up with the demand.
MAJOR COMPONENTS LIST
Item Description Qty Part No. Item Description Qty Part No.
1 Two Post Ram 1 67081 3 Basic Pump Assembly 1 650891-G43
2 Follower Plate 1 66516-1 4 Air Manifold 1 65940