Ingersoll-Rand LM2350E-XX-B Marine Sanitation System User Manual


 
LM2350E-X-B
Page2of4
PARTS LIST / LM2350E-XX-B
Item Description (size in inches) Qty Part No. [Mtl] Item Description (size in inches) Qty Part No. [Mtl]
1 Carriage Bolt (1/4” - 20 x 9” long) (4) 94333 [C]
2 Upper Cap (1) 94390 [Z]
n 3 Track Gasket (2) 94392 [B]
4 Sleeve (2) 94316 [Br]
n 5 “O” Ring (1/16” x 11/16” o.d.) (4) Y325-15 [B]
n 6 “O” Ring (1/8” x 3/4” o.d.) (4) Y325-206 [B]
7 Spool (2) 94310 [D]
n 8 “U” Cup (1/8” x 3/4” o.d.) (2) Y240-7 [B]
n 9 “O” Ring (.106” x .587” o.d.) (2) 15066-PM [B]
10 Cylinder (1) 94306 [A]
11 Adapter models LM2350E-X1-B (1) 94384 [C]
models LM2350E-X2-B (1) 94384-1 [C]
n 12 “O” Ring (1/16” x 3/4” o.d.) (1) Y325-16 [B]
n 13 “O” Ring (1/16” x 7/16” o.d.) (1) Y325-11 [B]
14 Muffler Housing (1) 94443 [A]
15 Foam Liner (2) 94402
16 Edge Trim (2) 94378-1 [N]
18 Retaining Ring (1) 94406 [C]
19 Washer (1) 94515 [C]
n 20 “U” Cup (3/16” x 3” o.d.) (2) 94518 [B]
21 Piston (1) 94403 [D]
23 Piston Adapter (1) 94388 [C]
n 24 “O” Ring (3/32” x 1” o.d.) (1) Y325-117 [B]
25 Dowel Pin (1/4” o.d. x 7/8” long) (1) Y148-37 [C]
26 Washer (1) 94785 [C]
n 27 “O” Ring (3/32” x 11/16” o.d.) (1) Y325-112 [B]
28 Spring (1) 94705 [C]
n 29 Rod Seal (1) 93921 [U]
30 Base models LM2350E-X1-B (1) 67188 [C/Z]
models LM2350E-X2-B (1) 67188-1 [C/ Z]
31 Nut (1/4” - 20) (4) 93828 [SS]
32 Ground Screw (#10 - 32 x 1/4”) (1) 93005 [C]
n 33 Gasket (1) 70834 [Co]
34 Extension Tube
- LM2350E-2X-B (7.531’’) (1) 94401-2 [C]
- LM2350E-3X-B (20.281’’) (1) 94401-3 [C]
- LM2350E-4X-B (28.781’’) (1) 94401-4 [C]
- LM2350E-6X-B (10.281’’) (1) 94401-6 [C]
- LM2350E-7X-B (18.531’’) (1) 94401-7 [C]
- LM2350E-8X-B (27.781’’) (1) 94401-8 [C]
n 35 Gasket (1) 70837 [Co]
36 Piston Rod (1) 94385 [C]
37 Pin (1) 94786 [C]
n 38 Cotter Pin (1/16” x 1/2” long) (1) Y15-21 [C]
39 Connector - LM2350E-2X-B (3.457”) (1) 94340-2 [C]
- LM2350E-3X-B (16.207”) (1) 94340-3 [C]
- LM2350E-4X-B (24.707”) (1) 94340-4 [C]
- LM2350E-6X-B (6.207”) (1) 94340-6 [C]
- LM2350E-7X-B (14.457”) (1) 94340-7 [C]
- LM2350E-8X-B (27.707”) (1) 94340-8 [C]
Piston & Tube Ass’y (includes 40- 44) (1) 71523-1
40 Lower Suction Tube (1) [C]
41 Plunger (1) [C]
42 Ball Stop (1) 83276 [C]
43 Ball (9/32” dia.) (1) Y16-209 [C]
44 Adapter (1) 70817-11 [C]
n 45 Guide Washer (1) 71524-1 [Co]
46 Spacer (1) 72392-1 [C]
47 Retaining Ring (.763” o.d.) (1) Y147-68 [C]
48 “U” Cup (3/16” x 11/16” o.d.) (1) Y186-4 [B]
49 Guide Spacer (1) 76705 [T]
50 Valve Body (1) 76704 [SH]
n Foot Valve Ass’y (includes 47 -50) (1) 60940
n 51 Gasket (1) F21-65 [Co]
52 Valve Seat (1) 6797 [C]
53 Primer Rod (1) 94446 [C]
n 54 Retainer Ring (1) 94397 [C]
55 Primer (1) 94400 [C]
56 Primer Tube (1) 94399 [C]
: 57 Bung Assembly (includes 58) (1) 67145-2 [ZA]
: 58 Thumb Screw (1/4”-20x1”) (3) Y66- 59-C [C]
: Not included with models LM2350E-6X-B
n Gadus S2 U1000 Grease Packet
(1)
94833
n Parts in Repair Kit 637227-B
OPERATING AND SAFETY PRECAUTIONS
WARNING
EXCESSIVE INLET PRESSURE. Can cause ex-
plosionresultinginsevereinjuryordeath. Donotexceedmaxi-
mum operating pressure of 7500 p.s.i. (517.2 bar) at 150 p.s.i.
(10.3 bar) inlet air pressure. Do not run pump w ithout using a
regulator to limit air supply pressure to the pump.
WARNING
EXCESSIVE MATERIAL PRESSURE. Can cause
equipment failure resulting in severe injury or property dam-
age. Do not exceed the maximum material pressure of any
component in the system.
Replacement warning label is available upon request, PN \ 94520.
PUMP RATIO X
INLET PRESSURE TO PUMP MOTOR
=
MAXIMUM PUMP
FLUID PRESSURE
Pumpratioisan expressionoftherelationshipbetweenthe pumpmotorareaand
the lower pumpend area.EXAMPLE: When150 p.s.i.(10.3bar) inletpressure is
suppliedto the motorof a50:1ratiopump itwill developa maximumof7500p.s.i.
(517.2bar)fluidpressure(atnoflow) -- as the fluidcontrolis opened,theflowrate
will increase as the motor cycle rate increases to keep up with the demand.
NOTICE:Thermalexpansioncan occurwhen thefluid inthemateri-
al lines is exposed to elevated temperatures. Example: Material
lines located in a non-insulated roof area can warm due to sunlight.
Install a pressure relief valve in the pumping system.