Jackson TS-66 Marine Battery User Manual


 
TS Series Conveyors Technical Manual 7610-002-98-29
Issued: 02-15-2006 Revised: N/A
SECTION 1: SPECIFICATION INFORMATION
ELECTRICAL REQUIREMENTS
3
NOTE: Typical Electrical Circuit is based upon (1) 125% of the full amperage load of the machine and (2) typical fixed-
trip circuit breaker sizes as listed in the NEC 2002 Edition. Local codes may require more stringent protection than
what is displayed here. Always verify with your electrical service contractor that your circuit protection is adequate
and meets all applicable national and local codes. These numbers are provided in this manual simply for reference
and may change without notice at any given time.
TS-44/TSC-44:
RINSE TYPICAL
HEATER TOTAL ELECTRICAL
VOL
TS PH HZ RATING AMPS CIRCUIT
208 1 60 N/A 83 Amps 110 Amp
230 1 60 N/A 76 Amps 100 Amp
208 3 60 N/A 49 Amps 70 Amp
230 3 60 N/A 45 Amps 60 Amp
460 3 60 N/A 23 Amps 30 Amp
600 3 60 N/A 19 Amps 25 Amp
TS-44GP/TSC-44GP:
RINSE TYPICAL
HEATER TOTAL ELECTRICAL
VOL
TS PH HZ RATING AMPS CIRCUIT
208 1 60 N/A 12 Amps 15 Amp
230 1 60 N/A 12 Amps 15 Amp
208 3 60 N/A 8 Amps 15 Amp
230 3 60 N/A 8 Amps 15 Amp
460 3 60 N/A 5 Amps 15 Amp
TS-66/TSC-66:
RINSE TYPICAL
HEATER TOTAL ELECTRICAL
VOL
TS PH HZ
RATING AMPS CIRCUIT
208 1 60 N/A 89 Amps 125 Amp
230 1 60 N/A 82 Amps 110 Amp
208 3 60 N/A 52 Amps 70 Amp
230 3 60 N/A 48 Amps 60 Amp
460 3 60 N/A 24 Amps 30 Amp
600 3 60 N/A 22 Amps 30 Amp
TS-66GP/TSC-66GP:
RINSE TYPICAL
HEATER TOTAL ELECTRICAL
VOL
TS PH HZ RATING AMPS CIRCUIT
208 1 60 N/A 18 Amps 25 Amp
230 1 60 N/A 18 Amps 25 Amp
208 3 60 N/A 12 Amps 15 Amp
230 3 60 N/A 12 Amps 15 Amp