3
1 INSTALLATION
FIXED STATION INSTALLATION
When you use the transceiver at a fixed location, the transceiver requires 13.8 V DC power supply
(The TS-480HX requires 2 DC power supplies).
REMOTE CONTROL PANEL INSTALLATION
1 Attach the oval-shaped base to the front panel mounting bracket using two SEMS screws (M4 x 10 mm) as
shown below.
2 Slide the Remote Control panel along the mounting bracket rails until secure.
DC POWER SUPPLY CONNECTION
In order to use this transceiver, you need a separate 13.8 V DC power supply (two 13.8 V/ 20.5 A or single
13.8 V/ 41.0 A DC power supply(s) is required to transmit for the TS-480HX) that must be purchased separately.
Do not directly connect the transceiver to an AC outlet. Use the supplied DC power cables to connect the
transceiver to a regulated power supply. Do not substitute a cable with smaller gauge wires. The current capacity
of each power supply must be 20.5 A peak or more.
1 Connect the DC power cable(s) to the regulated DC power supply (two 13.8 V/ 20.5 A or single 13.8 V/ 41.0 A
DC power supply(s) must be used for the TS-480HX); the red lead to the positive terminal and the black lead to
the negative terminal.
• When using a single 13.8 V/ 41 A DC power supply, connect 2 DC cables to the positive and negative
terminals, as shown on page 2.
2 Connect the DC power cable to the transceiver’s DC power connector.
• Press the connectors firmly until the locking tab clicks.
• Attach the line filter(s) to the DC cable(s) as shown below (E-type only).
Note:
◆
Before connecting the DC power supply to the transceiver, be sure to switch OFF the DC power supply and the transceiver.
◆
Do not plug the DC power supply into an AC outlet until you make all connections.
◆
When two power supplies are used for the TS-480HX, the DC voltage difference at the transceiver DC IN connectors must be within 1.0 V DC.
◆
Do not use different types (length and gauge) of DC cables to avoid voltage differences (TS-480HX).
DC
DC
13.8V
13.8V
1
DC 2 13.8V
AT
GNDGND
GND
2
2
1
Black (—)
Red (+)
Fuse (25 A)
DC IN 1
DC 13.8 V
DC Power supply
(20.5 A or more)
DC
13.8V13.8V
1
DC 2 13.8V
AT
GNDGNDGND
22
1
Black (–)
Red (+)
Fuse (25 A)
DC IN 1
DC 13.8 V
DC IN 2
DC 13.8 V
Red (+)
Fuse (25 A)
DC Power supply
(20.5 A or more)
DC Power supply
(20.5 A or more)
TS-480SAT TS-480HX
E-type only
SEMS screw
(M4 x 10 mm)
Panel holder
Base stand
SEMS screw
(M4 x 10 mm)