La Crosse Technology S88907 Marine Radio User Manual


 
Model: S88907 www.lacrossetechnology.com/support Page | 10
Status
Indicator
Color
Too Humid
First Arrow
Blue
Humid
Second Arrow
Blue
Good
Third Arrow
Green
Dry
Fourth Arrow
Orange
Too Dry
Fifth Arrow
Orange
Heat Index/Dew Point
The HEAT/DEW button toggles between Heat Index, Dew Point, and Mold Risk.
Each feature will display for 10 seconds then return to default display if the
button is not pressed again.
Heat Index
Heat Index combines the effects of heat and humidity. It is the apparent temperature of
how hot it feels to a human being. As humidity increases, the body is unable to cool
effectively; therefore, the temperature will feel warmer.
View Heat Index: From a normal display, press the HEAT/DEW button once and Heat
Index will show in place of the remote temperature.
Dew Point Temperature
Dew Point Temperature is the saturation point of the air, or the temperature to which the
air has to cool in order to create condensation. The higher the dew points, the higher the
moisture content of the air at a given temperature.
View Dew Point Temperature: From a normal display, press the HEAT/DEW button
twice and Dew Point will show place of the remote temperature.
Note: Dew Point is lower than the actual temperature.
Temperature/Humidity Trend indicators
The indoor and remote temperature/humidity trend indicators will update every 30
minutes or less. These trends represent temperature changes over the past three hours.
Example: At 1:00pm, the arrow indicates the change in temperature since 10:00am. At
1:30pm, the arrow will indicate the temperature change since 10:30am.
Temperature has risen in the past 3 hours.
Humidity has risen in the past 3 hours.
Temperature has not changed in the past 3 hours.
Humidity has not changed in the past 3 hours.
Temperature has fallen in the past 3 hours.
Humidity has fallen in the past 3 hours.