27. On Timer Input (Command: f u)
ToselectanexternalinputforthecurrentOnTime
settingandaddanewscheduleorchangethe
existingschedule.
Transmission
[f][u][][SetID][][Data1][Cr]
[f][u][][SetID][][Data1][Data2][Cr]
Data(Addschedule)
20:Input(AV)
40:Component
60.RGB
70:DVI-D
90:HDMI(HDMI1)
C0:DisplayPort
91:HDMI2/SDI
B0:SuperSign
Data1(Changeschedule)
1.F1toF7(Readdata)
F1:Selectthe1stscheduleinput
F2:Selectthe2ndscheduleinput
F3:Selectthe3rdscheduleinput
F4:Selectthe4thscheduleinput
F5:Selectthe5thscheduleinput
F6:Selectthe6thscheduleinput
F7:Selectthe7thscheduleinput
Data2
20:Input(AV)
40:Component
60:RGB
70:DVI-D
90:HDMI(HDMI1)
C0:DisplayPort
91:HDMI2/SDI
B0:SuperSign
*Toreadthescheduleinput,enterFFHfor[Data2].
Ifnoscheduleisavailablefor[Data1]when
attemptingtoreadorchangethescheduledata,the
textNGwillbedisplayedandtheoperationfails.
(Example1:fu0160-Moveeachscheduleinput
downonerowandsavethe1stscheduleinputin
RGBmode.)
(Example2:fu01f1ff-Readthe1stscheduleinput.)
(Example3:fu01f320-Changethe3rddata
scheduleinputtothecurrentOnTimeandAVinput.
Ifthereisnothirdschedule,thetextNGwillbe
displayedandtheoperationfails.)
*Thisfunctionissupportedonlywhen1(Year/Month/
Day),2(Hour/Minute/Second),OnTime(Repeat
Mode/Time)areset.
**Itmaynotbesupporteddependingonthemodel.
Acknowledgement
[u][][SetID][][OK/NG][Data][x]
[u][][SetID][][OK/NG][Data1][Data2][x]
28. Sleep Time (Command: f f)
TosettheSleepTime.
Transmission
[f][f][][SetID][][Data][Cr]
Data 00:Off(SleepTimeroff)
01:10min.
02:20min.
03:30min.
04:60min.
05:90min.
06:120min.
07:180min.
08:240min.
Acknowledgement
[f][][SetID][][OK/NG][Data][x]
29. Power On Delay (Command: f h)
Tosetthescheduledelaywhenthepoweristurned
on.(Unit:Second)
Transmission
[f][h][][SetID][][Data][Cr]
Data 00to64:min.0tomax.100(sec.)
Acknowledgement
[h][][SetID][][OK/NG][Data][x]
30. Automatic Standby (Command: m n)
TosettheAutomaticStandbyfunction.
Transmission
[m][n][][SetID][][Data][Cr]
Data 00:Off(Nooffafter4hours)
01:4Hours(Offafter4hours)
Acknowledgement
[n][][SetID][][OK/NG][Data][x]