Multiquip MQ41TDH Marine Sanitation System User Manual


 
MQ41TDH TRASH PUMP — PARTS & OPERATION MANUAL — REV. #3 (04/02/07) — PAGE 23
MQ41TDH — PREPARATIO
Pump Storage
For storage of the pump for over 30 days, the following is
required:
z
Drain the fuel tank completely.
z
Run the engine until the fuel in the injection system is
completely consumed.
z
Completely drain used oil from the engine crankcase
and fill with fresh clean oil, then follow the procedures
described in the engine manual for engine storage.
z
Remove the drain plug from the pump and drain out any
water from left in the housing.
z
Remove the pump cover and clean inside of pump
housing. Coat inside of pump housing with a light film of
oil to reduce corrosion. A spray can of oil works well for
this application.
z
Cover suction and discharge ports with duct tape to
prevent any foreign matter from falling into pump.
z
Cover pump and engine with plastic covering or
equivalent and store in a clean, dry place.
MQ41TDH — PUMP STORAGE