Mustang Survival MD3095 Life Jacket User Manual


 
portion of the LP in accordance with the CARE AND MAINTENANCE
INSTRUCTIONS.
CARE AND MAINTENANCE INSTRUCTIONS
The life preserver and inflation system should be checked at least
every three months. In addition, the following maintenance should be
performed after each time you wear or inflate the LP.
1) Remove and inspect the CO
2
cylinder from the inflator.
2) Check all components for dirt or corrosion. Clean or replace.
3) Check that the CO
2
cylinder has not been pierced. Replace with
MD3090 33gm CO
2
cylinder if necessary (contained in MD3090
accessory pack MA7170). Replace with MD3095 33gm CO
2
cylinder
if necessary (contained in MD3095 accessory pack MA7203).
4) Check the manual lever to ensure it is in the up and ready position,
with the green indicator pin properly installed (MD3090 only).
5) To check the oral inflation valve, fully inflate the MD3090 or MD3095
and hold the valve under water. If bubbles appear, deflate and
reinflate to test again. Should the leak persist, take your MD3090 or
MD3095 to the point of purchase for proper servicing.
6) Visually examine your MD3090 or MD3095 for damage or excessive
abrasion, wear, tear or contamination. Particular attention must be
paid to the stitching. If in doubt, send it to the point of purchase for
evaluation and/or servicing.
7) Reassemble inflation system parts and repack MD3090 or MD3095
as outlined in previous instructions and illustrations.
Leak test: Every three months the LP should be tested for general
leakage by orally inflating until firm and let stand overnight. A leaking LP
will not hold its firmness and should be replaced.
WARNING: If you are not confident in the self inspection and
servicing of your LP, in accordance with these instructions,
take your MD3090 or MD3095 LP to the point of purchase for
professional servicing or contact Mustang Survival (see contact
information on back of manual).
Compact Tactical Life Preserver Owner’s Manual 8 9 Compact Tactical Life Preserver Owner’s Manual